Check out some examples of possible arrangements with AcouS STIFF® software. This list is not exhaustive.
Click on individual cases of applications for more details.
SIDING |
• Double skin :
|
|
Double skin cladding with a double skin steel tray 75/100 + VN30 + VN70 + steel cladding of 75/100
Calculation : RW = 46
Measure : RW = 45
|
|
Click on picture to enlarge
|
|
|
• Steel deck 75/100 :
|
|
Steel of 0.75 mm
Calculation : RW = 23
Measure : RW = 22
|
|
Click on picture to enlarge
|
|
|
• Steel deck 63/100 :
|
|
Steel of 0.63 mm
Calculation : RW = 16
Measure : RW = 15
|
|
Click on picture to enlarge
|
|
|
CONCRETE |
• Reinforced concrete, 8 cm :
|
|
Reinforced concrete, 8 cm
Calculation : RW = 46
Measure : RW = 47
|
|
Click on picture to enlarge
|
|
|
• Reinforced concrete, 10 cm :
|
|
Reinforced concrete, 10 cm
Calculation : RW = 49
Measure: RW = 48 à 51
|
|
Click on picture to enlarge
|
|
|
CELLULAR CONCRETE |
• Cellular concrete 14 cm :
|
|
Cellular concrete 14 cm
Calculation : RW = 41
Measure : RW = 40
|
|
Click on the picture to enlarge
|
|
|
• Cellular concrete 20 cm :
|
|
20 cm aerated front coated concrete
Calculation : RW = 46
Measure : RW = 46
|
|
Click on picture to enlarge
|
|
|
DOUBLING |
• Gypsum :
|
|
Doubling on gypsum :
Gypsum 7 cm + glass wool rigid than 5 cm + 1 BA10
Calculation : RW = 56
Measure : RW = 55
|
|
Click on picture to enlarge
|
|
|
• Reinforced concrete 20 cm :
|
|
Doubling on concrete 20 cm :
reinforced concrete 20 cm + 8 cm glass wool rigid + 1 BA10
Calculation : RW = 71
Measure : RW = 73
|
|
Click on picture to enlarge
|
|
|
• Brick :
|
|
Doubling on brick :
Brick hollow 5 cm with an air gap of 1 cm + 3 cm of glass wool rigid + 1 BA10
Calculation : RW = 54
Measure : RW = 54
|
|
Click on picture to enlarge
|
|
|
• Frame :
|
|
Doubling on frame :
Reinforced concrete 16 cm + 3,5 cm air gap + 7,5 cm of glass wool a semi rigid +1 BA13
Calculation : RW = 74
Measure : RW = 74
|
|
Click on picture to enlarge
|
|
|
FLOOR |
• Wood floor :
|
|
1 wood panel (CTBH) de 22 mm + 165 mm air and 200 mm IBR + 1BA13
Calculation : RW = 61
Measure : RW = 62
|
|
Click on picture to enlarge
|
|
|
• Floating floor :
|
|
Reinforced concrete 14 cm with Rocksol 15 mm mortar and a cap of 4 cm
Calculation : RW = 58
Measure : RW = 58
|
|
Click on picture to enlarge
|
|
|
|
|
|
|
GLAZING |
• Single glass :
|
|
Glass 6 mm
Calculation : RW = 29
Measure : RW = 30
|
|
Click on picture to enlarge
|
|
|
• Laminated glass :
|
|
Laminated glass consists of a 5 mm glass + viscoelastic + 5 mm glass
Calculation : RW = 38
Measure : RW = 39
|
|
Click on picture to enlarge
|
|
|
• Double glazing 44.2/20/55.2 :
|
|
2 laminated glass 4 mm, air gap of 20 mm and 2, 5 mm laminated panes of glass
Calculation : RW = 48
Measure : RW = 47 à 49
|
|